DE715 GC Generator Set

Back to Home

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Pricing: Contact for Pricing

Request a quote

Request a New Equipment Quote

Fill out this form below and we will get back to you within 1 to 2 business days! Alternatively, give us a call at 833-286-3561


    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Request Machine Walkaround

    Find a Dealer Near You

    Duty Cycle Standby
    Emissions/Fuel Strategy Non Regulated
    Frequency 50 Hz
    Maximum Rating 715 kVA
    Minimum Rating 715 kVA
    Speed 1500 rpm
    Voltage 380 to 415 Volts
    Aspiration Turbocharged Air-to-Air Aftercooled
    Bore 5.4in
    Compression Ratio 16.1:1
    Displacement 928in³
    Engine Model C15 In-line 6, 4-cycle diesel
    Fuel System EUI
    Governor Type Adem™A4
    Stroke 6.8in
    Dry Weight - Genset (maximum) 8613lb
    Height - Maximum 86.1in
    Length - Maximum 131in
    Width - Maximum 60.6in

    Standard Equipment:

    • Cat® C15 Inline 6 cylinder, 4 stroke diesel
    • Air cleaner
    • GCCP 1.1
    • Mechanical governor
    • A Frame standard alternator
    • Package mounted radiator
    • Single wall 8 hour fuel tank
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
    • Secondary fuel filters
    • Primary fuel filter with integral water separator
    • Fuel priming pump
    • 3 Pole Circuit breaker
    • Neutral earth link
    • 24 Volt battery with rack and cables
    • Air cleaner; light duty with disposable element
    • Matched to the performance and output characteristics of Cat engines
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
    • IP23 Protection
    • Lubricating oil
    • Oil drain line with valve
    • Captive linear vibration isolators
    • Lifting provision and drag points
    • Busbar
    • Power center, IP22
    • Segregated low voltage (AC/DC) wiring panel
    • Integrated voltage regulator (IVR)
    • Optional LC Frame generator - IP23 Protection
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
    • Rubber vibration isolators
    • Cat electronic governor (ADEM A4).
    • Oil cooler
    • Oil drain valves
    • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
    • 24 Volt battery with rack and cables
    • Engine and alternator pre paint, Caterpillar yellow
    • Engine and alternator pre paint, Caterpillar yellow

    Optional Equipment:

    • Speed and Voltage adjust potentiometers
    • PLG 4G/3G/Ethernet
    • Annunciator
    • Emergency E-Stop
    • Industrial, residential, critical mufflers
    • Cat GC enclosure
    • Anti-condensation heater
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Oversize and premium generators
    • 4 Pole Circuit breaker
    • Auxiliary contacts
    • Padlockable circuit breaker
    • Battery charger
    • Wet battery
    • Circuit breakers, IEC compliant
    • Circuit breakers, UL listed
    • Space heater
    • AVR
    • Dual wall 8 hour fuel tank
    • Single wall 8 hour fuel tank with spill containment
    • Low fuel level shutdown
    • Low and high fuel level alarms
    • Fuel transfer system controls
    • Manual fuel transfer pump
    • Dual wall fuel tank base
    • Permanent magnet excitation (PMG) generator
    • Oversize A Frame generator
    • Ingress protection
    • LC frame CIP generator
    • LC frame generator
    • Oversize LC frame generator
    • CIP A Frame generator
    • Space heaters
    • Battery chargers
    • Heavy duty starting system
    • Charging alternator
    • Oversize batteries
    • Jacket water heater
    • Industrial silencer
    • 10 dBA Attenuation silencer
    • Engine mounted muffler
    • Manifold and turbocharger guards
    • End in/end out mufflers - 10, 25 and 35 dBA attenuation
    • 6 and 8 inch elbow kit
    • Flexible exhaust fittings
    • 6 and 8 inch flange GP
    • Single stage air filter
    • Dual element air filter
    • EU Certificate of Conformance (CE)
    • EAC Certification
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • EU Certificate of Conformance (CE)
    • The following options are based on regional and product configuration:
    • Narrow, wide or skid base
    • Automatic transfer switches (ATS)
    • Single or dual wall sub-base fuel tanks
    • EEC Declaration of Conformity
    • CSA Certification
    • UL 2200 package
    • Integral & sub-base UL listed dual wall fuel tanks
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • Single or dual wall integral fuel tanks
    • 3, 4, 5 and 10 Years
    • High ambient sound attenuated enclosures
    • Manual sump pump
    • Narrow skid base - replaces standard fuel tank base
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
    • 5 Amp single Battery charger
    • Battery disconnect switch
    • Jacket water heater

    Explore the features and Benefits
    of the DE715 GC Generator Set

    What Our Customers Are Saying About Us

    Gregory Poole Equipment Company place picture
    3.9
    Based on 46 reviews
    powered by Google
    David Lawrence profile pictureDavid Lawrence
    13:04 22 Feb 24
    Brandon Pierce profile pictureBrandon Pierce
    22:00 18 Feb 24
    Darin Noe profile pictureDarin Noe
    01:17 16 Feb 24
    Jose Soto profile pictureJose Soto
    15:26 23 Sep 23
    Hunter Elliott profile pictureHunter Elliott
    16:17 07 Sep 23
    Rick Kelly-Crapse profile pictureRick Kelly-Crapse
    21:06 25 Aug 23
    They had all my parts for my 3208 Cat.
    Friendly folks at parts counter.