C7.1 Generator Set

Back to Home

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Pricing: Contact for Pricing

Request a quote
Duty Cycle Standby, Prime
Emissions/Fuel Strategy Tier 3
Frequency 60 Hz
Maximum Rating 200 ekW
Minimum Rating 114 ekW
Speed 1800 rpm
Voltage 208 to 480 Volts
Aspiration Turbocharged, Air to Air Aftercooled
Bore 4.13in
Compression Ratio 16.5:1
Displacement 427.8in³
Engine Model C7.1 I-6, 4-Cycle Diesel
Fuel System Common Rail
Governor Type ADEM™A4
Stroke 5.31in
Height - Maximum 64in
Length - Maximum 98.4in
Width - Maximum 52in

Standard Equipment:

  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Control Panels
    • GCCP 1.3
  • Cooling System
    • Radiator and cooling fan with guards
    • Coolant drain line with valves
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
  • Generator And Generator Attachments
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • 12 Leads
    • IP23 Protection
    • Voltage regulator (single phase sensing)
    • Segregated low voltage (AC/DC) wiring panel
    • Tower panel, IP22, bottom cable entry
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Base, formed steel with single wall integral 8-hour fuel tank
    • Standard open set fuel tank/base supplied
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Termination points for coolant and lube oil drain lines
    • Includes lifting provision and drag points
  • Starting / Charging System
    • 24V battery with rack and cables
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Alternator System
    • R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
    • Permanent magnet excitation (PMG)
    • 3 Phase sensing
    • Optional LC Frame alternator with coastal insulation protection
    • Alternator removal
    • Anti-condensation heater
    • Quatrature droop king
  • Circuit Breakers
    • Padlockable breaker device
    • 4 Pole 250A, 400A and 630A Circuit breakers
  • Control Panel Options
    • Speed adjust contacts
    • Overload shutdown via breaker
    • Volt free contacts
    • Earth leakage (2 wire only)
    • Emergency stop with key
    • Battery charger
    • Panel mounted audible alarm
    • Earth fault (2 wire only)
    • Speed adjust potentiometer
  • Control System
    • GCCP 1.3
    • Volt free contacts for generator set running
    • Control panel heater
    • Volt free contacts for common alarm
    • Static battery charger
  • Cooling System
    • Low coolant level shutdown
    • Low coolant temperature
    • Coolant heater
  • European Certifications
    • Upgrade to STD set for CE
  • Enclosures
    • Sound attenuated levels 1 and 2 enclosures
    • Rental options (CAE only) - CEE form sockets for enclosure
    • Rental options (CAE only) - Socket blanking plate
    • Rental options (CAE only) - Rental pack
    • Rental options (CAE only) - Single point lift
  • Mounting Options
    • Silencer installation kit
    • Battery removal
    • Electronic governor
    • Residential silencer
    • Industrial silencer removal
  • Fuel Systems
    • Compact skidbase for open sets
    • Low fuel level shutdown
    • DEFRA bunded fuel tank
    • Skidbase for CALG enclosure sets
    • Low fuel level alarm
    • High fuel level alarm
    • Open set narrow tankbase
  • Test Reports
    • PGS Test report @ 0.8 power factor
    • PGS Test report @ 1.0 power factor
  • General
    • Stone guards/radiator trans flange
  • Global Certifications
    • Certification for CIS
  • Power Termination
    • Circuit breaker, IEC, 4 pole
  • Accessories / Miscellaneous
    • Packing case - canopied set
    • Packing case - compact set
Renee HerndonRenee Herndon
21:55 29 Feb 24
Dalton was very helpful, The road construction, however, was not! 😂I would rather have to sand paper an alligators @$$ in a phone booth that to get in that mess again.
Michael BirrenMichael Birren
14:58 24 Feb 24
I purchased a used C-15 from a customer of Greg Pool was a running take out. I picked up the engine from the Greg Pool Cat near Nags Head NC. They started they had done all service on this engine stated the hours and all items replaced during the life of engine under their care. I just recently put the engine in my boat after 2 years of building the vessel I find that everything they said about the engine was a LIE!!! Turbo was Bad, After cooler was not updated to the newer version for the C-15 it was missing a terminal Resistor that was clearly stolen off the engine which created a major issue with start up upon installation. Greg Pool Caterpillar stated the hours at 3300 we find out there were 5700 hours. I didn’t do a start up or test run which I regret because i was dealing with a Caterpillar dealer i thought i could trust them. Clearly not Buyers Be Ware if your dealing with Greg Pool Caterpillar in NC. I have 3 of the C-15 engines in my Work boats here in Tampa Fl and my Cat dealership here is Ring power who have done an amazing job to get me going with this Engine. I am very Disappointed in The Caterpillar company for allowing such A dealership to exist.
David LawrenceDavid Lawrence
13:04 22 Feb 24
Brandon PierceBrandon Pierce
22:00 18 Feb 24
Darin NoeDarin Noe
01:17 16 Feb 24
Jose SotoJose Soto
15:26 23 Sep 23
Hunter ElliottHunter Elliott
16:17 07 Sep 23
Rick Kelly-CrapseRick Kelly-Crapse
21:06 25 Aug 23
They had all my parts for my 3208 Cat.Friendly folks at parts counter.
js_loader