    Duty Cycle Standby, Prime
    Emissions/Fuel Strategy Non Regulated, EU Stage II
    Frequency 60 Hz
    Maximum Rating 100 ekW
    Minimum Rating 36 ekW
    Speed 1800 rpm
    Voltage 220 to 480 Volts
    Aspiration Turbocharged
    Bore 4.13in
    Compression Ratio 18.2:1
    Displacement 268.5in
    Engine Model C4.4, In-line 4, 4-cycle diesel
    Fuel System Electronic (adjustable)
    Governor Type Adem™A4
    Stroke 5in
    Height - Maximum 53.6in
    Length - Maximum 75.8in
    Width - Maximum 44.1in

    Standard Equipment:

    • Air cleaner; light duty with disposable element
    • Air cleaner
    • Package mounted radiator
    • Fan drive, battery charging alternator drive
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Caterpillar extended life coolant
    • Exhaust flange outlet
    • GCCP 1.3
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
    • Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
    • Secondary fuel filters
    • Primary fuel filter with integral water separator
    • Fuel priming pump
    • Segregated low voltage (AC/DC) wiring panel
    • Voltage regulator (single phase sensing)
    • Matched to the performance and output characteristics of Cat engines
    • 12 Leads
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • Tower panel, IP22, bottom cable entry
    • IP23 Protection
    • Mechanical and electrical governing system - model dependent
    • Lubricating oil
    • Oil drain line with valve
    • Busbar
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provision and drag points
    • Termination points for coolant and lube oil drain lines
    • Rubber vibration isolators
    • 24V battery with rack and cables
    • Paint - Caterpillar yellow except rails and radiators gloss black
    • Engine and alternator pre-paint, Caterpillar yellow
    • 24 volt starting motor
    • Batteries

    Optional Equipment:

    • Industrial, residential, critical mufflers
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Oversize and premium generators
    • Anti-condensation heater
    • 3 phase sensing
    • Permanent magnet excitation (PMG)
    • R Frame auxilliary winding
    • Quadrature droop kit
    • LC Frame alternator with coastal insulation protection
    • Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
    • Circuit breakers, IEC compliant
    • Circuit breakers, UL listed
    • GCCP 1.3
    • Load share module
    • Digital I/O module
    • Remote monitoring software
    • Local & remote annunciator modules
    • Coolant heater
    • Low coolant level shutdown
    • Low coolant temperature alarm
    • Earth fault (2 wire only)
    • GCCP 1.3
    • Volt free contacts
    • Emergency stop with key
    • Battery charger
    • Panel mounted audible alarm
    • Control panel heater
    • Speed adjust potentiometer
    • Voltage adjust potentiometer
    • Earth leakage (2 wire only)
    • Overload shutdown via breaker
    • Jacket water heater
    • Charging alternator
    • Heavy duty starting system
    • Battery chargers
    • Oversize batteries
    • Sound attenuated Level 2 enclosure
    • Sound attenuated Level 1 (galv)
    • Rental pack - CAE rental option only
    • Upgrade to STD set for CE
    • Compact skidbase for open set
    • Low fuel level alarm
    • Low fuel level shutdown
    • Bunded fuel tank
    • Open set narrow tankbase
    • Skidbase for CALG enclosure sets
    • High fuel level alarm
    • Single or dual wall sub-base fuel tanks
    • EU Certificate of Conformance (CE)
    • CSA Certification
    • Single or dual wall integral fuel tanks
    • Automatic transfer switches (ATS)
    • Narrow, wide or skid base
    • UL 2200 package
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • EEC Declaration of Conformity
    • Integral & sub-base fuel tanks
    • Certification for CIS
    • Battery removal
    • Electronic governor
    • Industrial silencer
    • Silencer installation kit
    • External single point lift - enclosure
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
    • Packing case - compact set
    • Stone guards/rad trans flange
    • Packing case - canopied set

    What Our Customers Are Saying About Us

    3.9
    Based on 46 reviews
    powered by Google
    Renee Herndon
    21:55 29 Feb 24
    Dalton was very helpful, The road construction, however, was not! 😂I would rather have to sand paper an alligators @$$ in a phone booth that to get in that mess again.
    David Lawrence
    13:04 22 Feb 24
    Brandon Pierce
    22:00 18 Feb 24
    Darin Noe
    01:17 16 Feb 24
    Jose Soto
    15:26 23 Sep 23
    Hunter Elliott
    16:17 07 Sep 23
    Rick Kelly-Crapse
    21:06 25 Aug 23
    They had all my parts for my 3208 Cat.Friendly folks at parts counter.
    js_loader