Service within 2 days — or when you say.

LEARN MORE

C15 (50 Hz) China Non Road

Back to Home

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Pricing: Contact for Pricing Why we quote: Cat® machines are often configured to your job (attachments, hydraulics, cab options) and freight/taxes can vary by location. Request a quote to get accurate pricing based on your exact setup—typically within 1–2 business days.

Request a quote

Request a New Equipment Quote

Fill out this form below and we will get back to you within 1 to 2 business days! Alternatively, give us a call at 833-286-3561


    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    No spam. We'll contact you within 1–2 business days.

    Request Machine Walkaround

    Find a Dealer Near You

    Duty Cycle Standby, Prime
    Emissions/Fuel Strategy Low Fuel, Tier 2 or 3
    Frequency 50 Hz
    Maximum Rating 550 kVA
    Minimum Rating 365 kVA
    Speed 1500 rpm
    Voltage 208 to 600 Volts
    Aspiration Air to Air Aftercooled
    Bore 5.4in
    Compression Ratio 16.1:1
    Displacement 927.56in³
    Engine Model C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
    Fuel System MEUI
    Governor Type Adem™A4
    Stroke 6.75in
    Height - Maximum 93.2in
    Length - Maximum 222.7in
    Width - Maximum 90in

    Standard Equipment:

    • Aftercooler core
    • Turbocharger
    • Air Cleaner - Non Canister disposable paper filter
    • Air Cleaner
    • EMCP 4.2
    • EMCP 4 Genset Controller
    • Package mounted radiator
    • Radiator and cooling fan with guard
    • Coolant drain line with valve
    • Caterpillar Extended Life Coolant
    • Fan drive, battery charging alternator drive
    • Secondary fuel filter
    • Fuel priming pump
    • Primary fuel filter with integral water separator
    • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
    • Exhaust flange outlet
    • Standard open set fuel tank / base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
    • IP23 Protection
    • Matched to the performance and output characteristics of Cat engines
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
    • IP23 Protection
    • A frame generator - IP21 Protection
    • Segregated low voltage (AC/DC) wiring panel
    • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power
    • Optional LC frame generator - IP23 Protection
    • Power center, IP22
    • Integrated Voltage Regulator
    • Bus Bar
    • Cat Electronic Governor (ADEM A4)
    • Lubricating oil
    • Oil drain valves
    • Rubber vibration isolators
    • Rubber vibration isolators
    • 24 Volt battery with rack and cables
    • Batteries
    • 24 volt starting motor
    • Engine and alternator pre paint, Caterpillar yellow
    • Paint - Caterpillar Yellow except rails and radiators gloss black

    Optional Equipment:

    • Single element air cleaner
    • Dual element air cleaner
    • Industrial, Residential, Critical Mufflers
    • EU certificate of conformance
    • Global certification for CIS
    • Oversize and premium generators
    • Anti-condensation heater
    • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
    • 4 Pole (IEC-100% rated) circuit breakers - Motorised
    • 3 Pole (IEC-100% rated) circuit breakers - Motorised
    • Auxiliary contacts, circuit breaker
    • 4 Pole (IEC-100% rated) circuit breakers - Package mounted
    • Pad-lockable circuit breaker device
    • Power terminal strip
    • Shunt trip for IEC circuit breaker
    • 3 Pole (IEC-100% rated) circuit breakers - Package mounted
    • Protective devices: Earth fault relay ; Earth leakage ground fault relay ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
    • Remote annunciator
    • Oil temperature displays
    • EMCP 4.3, EMCP 4.4
    • Local annunciator
    • Local alarm horn
    • Volt free contacts
    • Jacket water heater
    • Heavy-duty starting system
    • Battery chargers
    • Oversize batteries
    • Charging alternator
    • Radiator duct flange
    • Stone guards
    • Low coolant temperature alarm
    • Sound attenuated enclosures
    • High ambient sound attenuated enclosures
    • End in / End out mufflers - 10, 25 and 35 dBA attenuation
    • Manifold and turbocharger guard
    • Flexible exhaust fittings
    • 6 and 8 inch flange GP
    • 6 and 8 inch elbow kit
    • Engine mounted muffler
    • Dual wall fuel tank base
    • Manual fuel transfer pump
    • Fuel transfer system controls
    • UL 2200 package
    • Automatic transfer switches (ATS)
    • Narrow, Wide or Skid Base
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • Single or dual wall sub-base fuel tanks
    • EU Certificate of Conformance (CE)
    • EEC Declaration of Conformity
    • The following options are based on regional and product configuration:
    • Single or dual wall integral fuel tanks
    • CSA Certification
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • Integral & sub-base UL listed dual wall fuel tanks
    • Oversize A frame generator
    • LC frame generator
    • Oversize LC frame generator
    • CIP a frame generator
    • LC frame CIP generator
    • Permanent magnet generator
    • Space heaters
    • Ingress protection
    • Manual sump pump
    • Narrow skid base - replaces standard fuel tank base
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
    • 5 Amp single battery charger
    • Battery disconnect switch

    What Our Customers Are Saying About Us

    Gregory Poole Equipment Company place picture
    3.9
    Based on 46 reviews
    powered by Google
    David Lawrence profile picture
    David Lawrence
    13:04 22 Feb 24
    Brandon Pierce profile picture
    Brandon Pierce
    22:00 18 Feb 24
    Darin Noe profile picture
    Darin Noe
    01:17 16 Feb 24
    Jose Soto profile picture
    Jose Soto
    15:26 23 Sep 23
    Hunter Elliott profile picture
    Hunter Elliott
    16:17 07 Sep 23
    Rick Kelly-Crapse profile picture
    Rick Kelly-Crapse
    21:06 25 Aug 23
    They had all my parts for my 3208 Cat.
    Friendly folks at parts counter.