D600 GC (60 Hz) Generator Set

Back to

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Pricing: Contact for Pricing

Request a quote
Duty Cycle Standby
Emissions/Fuel Strategy EPA Stationary Emergency
Frequency 60 Hz
Maximum Rating 600 ekW
Minimum Rating 600 ekW
Speed 1800 rpm
Voltage 480 to 600 Volts
Aspiration Turbocharged Air-to-Air Aftercooled
Bore 5.7in
Compression Ratio 14.5:1
Displacement 1106in³
Engine Model Cat® C18 In-line 6, 4-cycle Diesel
Fuel System MEUI
Governor Type ADEM™A4
Stroke 7.2in
Dry Weight - Genset (maximum) 11647lb
Dry Weight - Genset (minimum) 8959.6lb
Height - Maximum 100.9in
Height - Minimum 79.1in
Length - Maximum 196.1in
Width - Maximum 73.4in

Standard Equipment:

  • Air Inlet System
    • Turbocharger
    • Air cleaner - Non canister, disposable
    • Aftercooler core
  • Control Panel
    • GCCP 1.2
  • Cooling System
    • Radiator sight gauge
    • Thermostats and housing
    • Coolant drain valve
    • Jacket water pump, gear driven, centrifugal
    • Blower fan and fan drive with guards
    • Radiator, package mounted
  • Exhaust System
    • Exhaust manifold - dry
  • Fuel System
    • Fuel cooler
    • Primary fuel filter w/integral water separator and secondary filter, spin on
    • Integral tank base, 24 hours, UL142
    • Engine fuel transfer pump
    • Fuel priming pump
  • Generator Set
    • Complete system designed & built at ISO 9001:2000 certified facilities
    • Factory tested to design specifications at full load conditions
    • All protective devices and control functions simulated and checked
  • Generators And Generator Attachments
    • 6 Leads
    • Voltage regulator (single phase sensing)
    • Easy access to AVR and terminals
    • Insulation system, Class H
    • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
    • Terminal box, IP22 RHS facing, bottom cable entry
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • IP23 Protection
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Oil filler and dipstick
    • Shallow oil pan
    • Oil filter, spin on
    • Oil cooler
    • Lubricating oil, CK-4 (10W-30)
    • Oil drain with valve
    • Fumes disposal to front of radiator
  • Mounting System
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
    • Captive linear vibration isolators between base and engine-generator
  • Protection
    • Safety shutoff - High water temperature
    • Safety shutoff - Overspeed
    • Safety shutoff - Low oil pressure
  • Starting/charging System
    • 24V, 45 Amp Charging alternator
    • 24-volt electric starting motor
  • General
    • Parts book
    • Vibration damper
    • Lifting eyes

Optional Equipment:

  • Air Inlet System
    • Air cleaner (Non canister disposable)
  • Bases, Mounting & Fuel Tanks
    • Audio & visual fuel alarm (@90% fuel level)
    • Integral tank base, 24 hours, UL142
    • 5 Gallon Spill Containment
    • Overfill prevention valve
    • Fuel tank pill pipe & lockable cap
    • Wide Base - Skid
  • Circuit Breaker
    • 400A LSI
    • Auxiliary contacts
    • 400A LS/I
    • 800A LSI
    • 600A LSI
    • 1200A LS/I
    • 800A LS/I
    • 600A LS/I
    • 1200A LSI
  • Control System
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • Ground fault relay
    • 16 -light NFPA 99/110 Annunciator
    • Volt free contacts
    • Twist release, Red button emergency stop
    • 100A Load center
    • Product link remote monitoring hardware
    • Audible alarm Gp
    • Earth (Ground) fault relay
    • Volt free contact
    • Remote E-Stop button
    • Discrete I/O module
    • Annunciators box
    • Local annunciator
  • Exhaust System
    • 8" Muffler - 25 dBA attenuation
    • Flexible exhaust connection
    • Manifold and turbocharger guards
  • Generator
    • Space heater
    • Permanent magnet excitation (PMG) generator
  • Starting System
    • Jacket water heater
    • Standard battery set: 1000 CCA, 90 amp/hr.
    • Battery charger (UL Certified)
    • Oversize battery set, 1400 CCA, 200 amp/hr
  • General
    • Extended Service Coverage
    • Generator test report
    • CSA Certification
    • UL2200 Certification
    • Tool set
  • Circuit Breakers
    • Single LSI motorised circuit breaker
    • Single LSI motorised circuit breaker
    • Auxiliary contacts
    • Neutral bar (208V)
  • Enclosures
    • E-Stop
    • Sound attenuated Level 2 enclosure (White)
    • AC & DC Source lights
    • Sound attenuated enclosure
  • Cooling System
    • Coolant heater
    • Stone guards
    • Jacket water heater with pump
  • Base / Fuel Tank
    • Audio & visual fuel alarm
  • Fuel System
    • Integral 8 hour tank base
  • Starting And Charging
    • Oversize battery set
    • Standard battery set
    • 5 Amp Battery charger
    • Battery disconnect switch
  • Certifications
    • CSA 22.2
    • UL2200 Listed
    • Seismic
  • Lube System
    • Manual sump pump

What Our Customers Are Saying About Us

Renee HerndonRenee Herndon
21:55 29 Feb 24
Dalton was very helpful, The road construction, however, was not! 😂I would rather have to sand paper an alligators @$$ in a phone booth that to get in that mess again.
David LawrenceDavid Lawrence
13:04 22 Feb 24
Brandon PierceBrandon Pierce
22:00 18 Feb 24
Darin NoeDarin Noe
01:17 16 Feb 24
Jose SotoJose Soto
15:26 23 Sep 23
Hunter ElliottHunter Elliott
16:17 07 Sep 23
Rick Kelly-CrapseRick Kelly-Crapse
21:06 25 Aug 23
They had all my parts for my 3208 Cat.Friendly folks at parts counter.
js_loader