DE88 GC Generator Set (60 Hz)

Back to

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Pricing: Contact for Pricing

Request a quote
Duty Cycle Standby
Emissions/Fuel Strategy Non Regulated
Frequency 60 Hz
Maximum Rating 80 ekW
Minimum Rating 80 ekW
Speed 1800 rpm
Voltage 220 to 480 Volts
Aspiration Turbocharged
Bore 4.1in
Compression Ratio 17.25:1
Displacement 268.5in
Engine Model C4.4, In-line 4, 4-cycle diesel
Fuel System Inline
Governor Type Mechanical
Stroke 5in
Dry Weight - Genset (maximum) 1245lb
Height - Maximum 57.7in
Length - Maximum 89.6in
Width - Maximum 43.3in

Standard Equipment:

  • Engine
    • C4.4, Inline 4 Cylinder, 4 Stroke Diesel
  • Governor
    • Mechanical Governor
  • Alternator
    • A Frame Standard Alternator
  • Fuel Storage
    • Single Wall 8 Hour Tank
  • Genset Control
    • GCCP 1.1
  • Enclosure
    • Cat GC Enclosure
  • Air, Cooling & Exhaust
    • Enclosure Silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance
  • Alternator Requirements
    • Space Heater
  • Fuel Storage
    • Low Fuel Level Shutdown
    • Single Wall Tank With Containment
    • Dual Wall 8 Hour Tank
    • Low Fuel Level Alarm
    • High Fuel Level Alarm
  • Genset Control
    • Volt Free Contacts for Genset Running
    • Earth Fault
    • Panel Mounted Audible Alarm
    • USB to RS485 Communications Device
    • Emergency Stop with Key
    • Earth Leakage
    • Battery Charger
    • Volt Free Contacts for Common Alarm
    • Coolant Heater
    • Standby Pack (Smart Jacket Water Heater, Battery Charger)
    • Battery
    • Low Coolant Level Shutdown
  • Circuit Breaker
    • 3 Pole Circuit Breaker 160A
    • 3 Pole Circuit Breaker 125A
    • 3 Pole Circuit Breaker 200A
    • 3 Pole Circuit Breaker 400A
    • 4 Pole Circuit Breaker 160A
    • 4 Pole Circuit Breaker 125A
    • 3 Pole Circuit Breaker 250A
    • 4 Pole Circuit Breaker 250A
    • 4 Pole Circuit Breaker 200A
    • Circuit Breaker Padlock
    • 4 Pole Circuit Breaker 400A
    • Neutral Earth Link
    • Overload via Alarm Switch on Breaker
  • Testing & Packaging
    • PGS Test Report @ 1.0PF
    • PGS Test Report @ 0.8PF

What Our Customers Are Saying About Us

Renee HerndonRenee Herndon
21:55 29 Feb 24
Dalton was very helpful, The road construction, however, was not! 😂I would rather have to sand paper an alligators @$$ in a phone booth that to get in that mess again.
David LawrenceDavid Lawrence
13:04 22 Feb 24
Brandon PierceBrandon Pierce
22:00 18 Feb 24
Darin NoeDarin Noe
01:17 16 Feb 24
Jose SotoJose Soto
15:26 23 Sep 23
Hunter ElliottHunter Elliott
16:17 07 Sep 23
Rick Kelly-CrapseRick Kelly-Crapse
21:06 25 Aug 23
They had all my parts for my 3208 Cat.Friendly folks at parts counter.
js_loader