DE33 GC Generator Set (60 Hz)

Back to Home

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Request a quote
Duty Cycle Standby
Emissions/Fuel Strategy Non Regulated
Frequency 60 Hz
Maximum Rating 30.0 ekW
Minimum Rating 30.0 ekW
Speed 1800 rpm
Voltage 220 to 480 Volts
Aspiration Naturally Aspirated
Bore 4.1in
Compression Ratio 19.25:1
Displacement 201.4in³
Engine Model Cat® C3.3, In-line 3, 4-cycle diesel
Fuel System Inline
Governor Type Mechanical
Stroke 5in
Dry Weight - Genset (maximum) 2114lb
Height - Maximum 48.7in
Length - Maximum 76.6in
Width - Maximum 34.3in

Standard Equipment:

  • Engine
    • C3.3, Inline 3 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour tank
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Alternator Requirements
    • Space heater
  • Auxiliary Supply Voltage
    • 120V
  • Fuel Storage
    • Dual wall 8 hour tank
    • Low fuel level shutdown
    • Single wall tank with containment
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Battery charger
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Earth fault
    • Panel mounted audible alarm
    • USB to RS485 communications device
    • Emergency stop with key
    • Earth leakage
    • Low coolant level shutdown
    • Coolant heater
    • Standby Pack (Smart jacket water heater, battery charger)
    • Battery
  • Circuit Breaker
    • 3 Pole circuit breaker 80A
    • 3 Pole circuit breaker 63A
    • 3 Pole circuit breaker 100A
    • 3 Pole circuit breaker 125A
    • 3 Pole circuit breaker 160A
    • 3 Pole circuit breaker 200A
    • 4 Pole circuit breaker 80A
    • 4 Pole circuit breaker 63A
    • 4 Pole circuit breaker 100A
    • 4 Pole circuit breaker 125A
    • 4 Pole circuit breaker 160A
    • 4 Pole circuit breaker 200A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test Report @ 1.0 power factor
    • PGS Test Report @ 0.8 power factor