3516C Generator Set

Back to Home

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Pricing: Contact for Pricing

Request a quote
Duty Cycle Standby, Mission Critical, Prime, Continuous
Emissions/Fuel Strategy U.S. EPA Cert., Tier 2
Frequency 60 Hz
Maximum Rating 2500 ekW
Minimum Rating 1650 ekW
Prime Power Rating 2250/2045/1825 ekW
Speed 1800 rpm
Standby Rating 2500/2250/2000 ekW
Voltage 380 to 13800 Volts
Aspiration TA
Bore 6.69in
Compression Ratio 14.7:1
Displacement 4764.73in
Engine Model 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel
Fuel System Electronic unit injection
Governor Type Adem™3
Stroke 7.48in
Stroke - HD 8.46in
Dry Weight - Genset (maximum) 38780lb
Dry Weight - Genset (minimum) 35880lb
Height - Maximum 118.5in
Height - Minimum 116.5in
Length - Maximum 295.1in
Length - Minimum 284.6in
Width - Maximum 101.2in
Width - Minimum 93.7in

Standard Equipment:

  • Air Inlet System
    • Air cleaner; single element canister type
  • Cooling
    • Package mounted radiator
  • Exhaust
    • Exhaust flange outlet
  • Control Panels
    • Communications:
    • Reverse reactive power (kVAr) (32RV)
    • Customer data link (Modbus RTU)
    • Generator mounted - rear facing
    • 1 Programmable digital outputs
    • Auto/start/stop control -
    • Serial annunciator module data link
    • Engine cool-down timer
    • 24 Volt DC operation
    • Controls:
    • Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
    • Alarm acknowledge
    • Cat connect
    • Engine cycle crank
    • Text alarm/event descriptions
    • Overcurrent (50 / 51)
    • Accessory module data link
    • Cat ECS 100
    • 1 Programmable relay outputs (Form C)
    • Emergency stop pushbutton
    • Speed adjust
    • 4 Programmable relay outputs (Form A)
    • Number of I/O varies on options selected
    • 6 Customer programmable digital inputs
    • Environmental sealed front face
    • Load histogram feature
    • Lamp test
    • PLC functionality
    • Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
    • Digital indication for:
    • Operating hours
    • RPM
    • DC volts
    • Frequency (Hz)
    • Coolant temperature
    • Volts (L-L & L-N)
    • Oil pressure (psi, kPa or bar)
    • Amps (per phase & average)
    • kVAr (per phase, average & percent)
    • kVA (per phase, average & percent)
    • kW (per phase, average & percent)
    • Power factor (per phase & average)
    • kW-hr (total)
    • kVAr-hr (total)
    • High coolant temperature
    • Overspeed
    • Failure to start (overcrank)
    • Warning/shutdown with common LED indication of shutdowns for:
    • Emergency stop
    • Low oil pressure
    • Low coolant level
    • Low coolant temperature
    • Programmable protective relaying functions:
    • Over/under frequency (81 o/u)
    • Generator phase sequence
    • Over/under voltage (27 / 59)
    • Reverse power (kW) (32)
  • Fuel
    • Primary fuel filter with integral water separator
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
  • Power Termination
    • Busbar
  • Control Panel
    • Cat ECS Genset controller
  • Cooling System
    • Certified standard PGS provided
  • Exhaust System
    • Flanged faced outlet(s)
    • Dry exhaust manifold
  • Fuel System
    • Flexible fuel lines - shipped loose
    • Fuel cooler; not included with packages without radiator
    • Secondary fuel filters
    • Fuel priming pump
  • General
    • Caterpillar yellow with high gloss black rails and radiator
    • Right hand servicing
    • Flywheel and flywheel housing - SAE No. 00
    • Paint - Caterpillar yellow except rails and radiators gloss black
    • SAE standard rotation
  • Generator And Attachments
    • Busbar connections, top center mounted, top cable entry
    • Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • Low voltage:
    • NEMA standard hole pattern
    • Medium voltage:
    • Anti-condensation space heater
    • 6 Lead
    • Random wound
    • Form wound
    • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • Permanent magnet excitation (PMG)
    • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
    • Internal excitation (IE)
    • 3 Phase brushless, Salient pole
    • High voltage:
    • Winding temperature detectors
    • Busbar connections, right side extension box, bottom cable entry
  • Governing System
    • ADEM A3
  • Literature
    • Parts book
  • Lubrication System
    • Lubricating oil
    • Fumes disposal
    • Integral lube oil cool
    • Oil drain lines and valve
    • Oil filter, filler and dipstick
    • Gear type lube oil pump
  • Mounting System
    • Anti-vibration mounts (shipped loose)
    • Rubber anti-vibration mounts - shipped loose
    • Rails - engine/generator/radiator mounting
  • Starting System
    • Battery disconnect switch
    • 45 Amp Charging alternator
    • 24 Volt electric starting motor
    • Battery and battery rack w/cables

Optional Equipment:

  • Control System
    • EMCP 4.4
  • Exhaust
    • Exhaust mufflers
  • Air Inlet System
    • Single element filter
    • Dual element air cleaner
  • Generator
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Oversize and premium generators
    • Anti-condensation heater
  • Cooling System
    • Coolant
    • Standard ambient ATAAC radiators
    • Optional installed radiators
    • Optional installed ATAAC radiators
    • Standard ambient radiators
    • Water level switch gauges
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Crankcase System
    • Explosion relief valves
    • Ventilation system
    • No explosion relief valves
  • Control Panels
    • Load share module
    • Digital I/O module
    • Generator temperature monitoring & protection
    • Remote monitoring software
  • Mounting
    • Rubber anti-vibration mounts
    • IBC isolators
  • Exhaust System
    • Y Adapters
    • Flexible fittings
    • Exhaust offset
    • Tier 4 clean emissions module
    • Elbows
    • Flange and exhaust expanders
    • Tier 4 clean emission MOD Kits
    • Tier 4 dosing cabinet
    • Flanges
    • Mufflers
    • Clean emission parts
  • Starting/charging
    • Oversize batteries
    • Battery chargers
    • Charging alternator
    • Air starting motor with control and silencer
    • Heavy duty starting system
  • Fuel System
    • Primary fuel filter
  • General
    • The following options are based on regional and product configuration:
    • UL 2200 package
    • CSA Certification
    • EEC Declaration of Conformity
    • Special paint (Colors other than Caterpillar yellow or high performance paints)
    • Integral & sub-base fuel tanks
    • US aid emblem
    • Enclosures: Sound attenuated, weather protective
    • Automatic transfer switches (ATS)
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • EU Certificate of Conformance (CE)
    • Integral & sub-base UL listed dual wall fuel tanks
  • Generators And Attachments
    • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • Thermostat for space heater
    • Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
    • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
    • Differential current transformers (DCT) 8.7 kV and 15 kV classes
    • Generator conversion
    • Space heater kit
    • Alternator air cleaner
  • Instrumentation
    • Pyrometer and thermocouples
  • Lubrication System
    • Oil level regulator
    • Lube oil in standard sump
    • Prelube pumps
  • Mounting System
    • Puck style low efficiency isolators
    • Spring type vibration isolators
    • IBC vibration isolators
  • Power Connections
    • Ground cables between generator and terminal box
    • Neutral ground connections
    • Left side power connections
    • Center post busbars
    • Right side power connections
    • 2700 Frame, four lead, four terminal
    • Rear power connections
    • Low voltage Circuit breakers
  • Special Tests / Reports
    • IBC Certification
    • Fuel consumption test
    • Generator test report
    • PGS Test report @ 1.0 power factor
    • Torsional vibration analysis reports
    • OSHPD Certification
    • Generator set fuel consumption test
    • PGS Test report @ 0.8 power factor
    • Standard engine test charge
    • Canadian Standards Association certification
  • Starting And Charging
    • Air pressure regulator
    • Starter cover
    • Air starting motors
    • 10, 20, 35 and 50 Amp Battery chargers
    • Electric starting motors
    • Jacket water heaters
    • 24 Volt battery set - Dry
    • Engine barring device
  • Extended Service Coverage
    • Platinum, Gold and Silver coverage
Renee HerndonRenee Herndon
21:55 29 Feb 24
Dalton was very helpful, The road construction, however, was not! 😂I would rather have to sand paper an alligators @$$ in a phone booth that to get in that mess again.
Michael BirrenMichael Birren
14:58 24 Feb 24
I purchased a used C-15 from a customer of Greg Pool was a running take out. I picked up the engine from the Greg Pool Cat near Nags Head NC. They started they had done all service on this engine stated the hours and all items replaced during the life of engine under their care. I just recently put the engine in my boat after 2 years of building the vessel I find that everything they said about the engine was a LIE!!! Turbo was Bad, After cooler was not updated to the newer version for the C-15 it was missing a terminal Resistor that was clearly stolen off the engine which created a major issue with start up upon installation. Greg Pool Caterpillar stated the hours at 3300 we find out there were 5700 hours. I didn’t do a start up or test run which I regret because i was dealing with a Caterpillar dealer i thought i could trust them. Clearly not Buyers Be Ware if your dealing with Greg Pool Caterpillar in NC. I have 3 of the C-15 engines in my Work boats here in Tampa Fl and my Cat dealership here is Ring power who have done an amazing job to get me going with this Engine. I am very Disappointed in The Caterpillar company for allowing such A dealership to exist.
David LawrenceDavid Lawrence
13:04 22 Feb 24
Brandon PierceBrandon Pierce
22:00 18 Feb 24
Darin NoeDarin Noe
01:17 16 Feb 24
Jose SotoJose Soto
15:26 23 Sep 23
Hunter ElliottHunter Elliott
16:17 07 Sep 23
Rick Kelly-CrapseRick Kelly-Crapse
21:06 25 Aug 23
They had all my parts for my 3208 Cat.Friendly folks at parts counter.