Pricing: Contact for Pricing

Request a quote
Duty Cycle Standby, Mission Critical, Prime, Continuous
Emissions/Fuel Strategy Low Fuel Consumption
Frequency 50 Hz
Maximum Rating 1400 kVA
Minimum Rating 1000 kVA
Prime Power Rating 1275/1150 kVA
Speed 1500 rpm
Standby Rating 1400/1250 kVA
Voltage 380 to 415 Volts
Aspiration TA
Bore 6.69in
Compression Ratio 13.5:1
Displacement 3161.03in³
Engine Model 3512 TA, V-12, 4-Stroke Water-Cooled Diesel
Fuel System Direct Unit Injection
Governor Type Woodward
Stroke 7.48in
Dry Weight - Genset (maximum) 23170lb
Dry Weight - Genset (minimum) 22650lb
Height - Maximum 93.2in
Length - Maximum 206.6in
Length - Minimum 202.7in
Width - Maximum 77.8in

Standard Equipment:

  • Air Inlet System
    • Air cleaner; single element canister type with service indicator
  • Control Panel
    • EMCP4.2B controls including: Emergency stop pushbutton
    • RPM
    • Engine cool-down timer
    • EMCP4.2B controller including:
    • Accessory module data link
    • 4 programmable relay outputs (Form A)
    • Communications:
    • Volts (L-L & L-N)
    • Over / under frequency (81 o / u)
    • Text alarm / event descriptions
    • Auto / start / stop control
    • Speed adjust
    • kVA (per phase, average & percent)
    • Overcurrent (50 / 51)
    • Alarm acknowledge
    • Environmental sealed front face
    • 6 programmable digital inputs
    • Oil pressure (psi, kPa or bar)
    • Amps (per phase & average)
    • Generator phase sequence
    • 2 Programmable digital outputs
    • Low coolant temperature
    • Controls:
    • Serial annunciator module data link
    • Reverse Power (kW) (32)
    • Lamp test
    • Coolant temperature
    • Engine cycle crank
    • kVAr-hr (total)
    • 2 Programmable relay outputs (Form C)
    • Generator mounted - rear facing
    • 24-volt DC operation
    • kVAr (per phase, average & percent)
    • Warning/shutdown with common LED indication of shutdowns for:
    • kW (per phase, average & percent)
    • Reverse Reactive Power (kVAr) (32RV)
    • Programmable protective relaying functions:
    • Digital indication for:
    • High coolant temperature
    • Low oil pressure
    • Overspeed
    • Over / under voltage (27 / 59)
    • Customer data link (Modbus RTU)
    • DC volts
    • Operating hours
    • Low coolant level
    • kW-hr (total)
    • Frequency (Hz)
    • Emergency stop
    • Power Factor (per phase & average)
    • Failure to start (overcrank)
    • True RMS AC metering, 3-phase, +/-2% accuracy
  • Cooling System
    • JWAC
    • Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
    • Radiator fan and fan drive
    • Fan and belt guards
    • Coolant drain line with valve
    • Coolant level sensors. (Not included with packages without radiator)
  • Exhaust System
    • Dry Exhaust Manifold
    • Flanged faced outlet(s)
  • Fuel System
    • Fuel cooler; not included with packages without radiator
    • Flexible fuel lines - shipped loose
    • Fuel priming pump
    • Secondary fuel filters
  • Generators And Attachments
    • Generator set packages include: Regulator (CDVR)
    • 6 Lead
    • Min / max exciter limiter
    • LV:
    • Reactive droop capability
    • Random wound
    • Exciter diode monitor
    • KVAR/PF modes
    • NEMA Class H insulation
    • 50 Hz models: IEC standard hole pattern
    • Caterpillar's Digital Voltage Regulator (CDVR) includes:
    • Note: 1800 frames are form wound, permanent magnet, with winding temp detectors
    • Busbar connections, top center mounted, top cable entry
    • Internal Excitation
    • Winding temperature detectors
    • Class H temperature rise at 40C ambient (125C prime/150C standby)
    • 3 Phase brushless, salient pole
    • 3 Phase voltage sensing
    • RFI suppression
  • Governing System
    • Woodward 2301A isochronous governor
  • Lube System
    • Oil drain lines and valve
    • Gear type lube oil pump
    • Fumes disposal
    • Oil filter, filler and dipstick
    • Lubricating oil
    • Integral lube oil cooler
  • Mounting System
    • Rubber anti-vibration mounts (shipped loose)
    • Rails - engine/generator/radiator mounting
  • Starting / Charging System
    • 24 Volt electric starting motor
    • Battery and battery rack w/cables
    • Battery disconnect switch
  • General
    • Paint - Caterpillar Yellow with high gloss black rails & radiator
    • SAE Standard Rotation
    • RH Service
    • Flywheel and Flywheel housing - SAE No. 00

Optional Equipment:

  • Air Inlet System
    • Remote air inlet adaptors
    • Air Inlet protection
    • Dual Element air cleaners
  • Circuit Breakers
    • EMAX circuit breakers
    • Center posts busbars
    • EMAX breakers connections
    • Breaker harnesses
    • 2000, 2500, 3200 and 4000 Amp, 4 pole, IEC rated circuit breakers
    • Controls packaging - Enclosures
    • Cable entry options
    • 2000, 2500, 3200 and 4000 Amp, 3 pole, IEC rated circuit breakers
    • Optional busbar power connections
    • Busbar connections
  • Control Panel
    • Auxiliary Boxes
    • Customer connection mounting locations
    • Ground (Automatically selected)
    • Vandle proof panel door
    • Customer Interface Options
    • Mounting Group - External Box Clips
    • Remote speed adjust
    • Generator Temperature Monitoring
    • Governors
    • Annunciator Modules
    • Local PC monitoring
  • Cooling System
    • Water level switch gauges
    • Heat exchangers
    • Optional radiator arrangements
  • European Certifications
    • EU declaration of conformity
    • Eurasian conformity (EAC) mark
    • European directive genset, DoI (Declaration of Incorporation)
    • European Union Certification
  • Exhaust System
    • Through-wall installation kit
    • Muffler mounting kits
    • Mufflers
    • Flexible fittings
  • Fuel System
    • Primary fuel filter
  • Generators And Attachments
    • 380 / 400 / 415 Volts @ 50 Hz, 3 phase, form wound, permanent magnet, No. of leads = 6, pitch= 0.6667
    • 380/400/415volts @ 50 Hz, 3 phase, random wound, permanent magnet, No. of leads = 6, pitch= 0.6667
    • Generator conversion
    • 380/400/415volts @ 50 Hz, 3 phase, random wound, internal excitation, No. of leads = 6, pitch= 0.6667
    • Space heater
  • Instrumentation
    • Pyrometer and thermocouples
  • Lube System
    • Electric prelube pumps
    • Oil level Reg-1 shallow pan
    • Manual prelube sump pumps
  • Mounting System
    • Spring-type vibration isolator
    • IBC vibration isolators
  • Protection System
    • Explosion relief valve
  • Special Tests / Reports
    • Neutral grounding connection
    • IBC seismic certifications
    • Neutral ground-LV
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
  • Starting / Charging Systems
    • Ether starting aid
    • 24 Volt dual electric starting motor
    • 20 Amp battery charger
    • Oversize battery set
    • Jacket water heaters
    • 10 Amp battery chargers
  • General
    • Engine barring group
Renee HerndonRenee Herndon
21:55 29 Feb 24
Dalton was very helpful, The road construction, however, was not! 😂I would rather have to sand paper an alligators @$$ in a phone booth that to get in that mess again.
Michael BirrenMichael Birren
14:58 24 Feb 24
I purchased a used C-15 from a customer of Greg Pool was a running take out. I picked up the engine from the Greg Pool Cat near Nags Head NC. They started they had done all service on this engine stated the hours and all items replaced during the life of engine under their care. I just recently put the engine in my boat after 2 years of building the vessel I find that everything they said about the engine was a LIE!!! Turbo was Bad, After cooler was not updated to the newer version for the C-15 it was missing a terminal Resistor that was clearly stolen off the engine which created a major issue with start up upon installation. Greg Pool Caterpillar stated the hours at 3300 we find out there were 5700 hours. I didn’t do a start up or test run which I regret because i was dealing with a Caterpillar dealer i thought i could trust them. Clearly not Buyers Be Ware if your dealing with Greg Pool Caterpillar in NC. I have 3 of the C-15 engines in my Work boats here in Tampa Fl and my Cat dealership here is Ring power who have done an amazing job to get me going with this Engine. I am very Disappointed in The Caterpillar company for allowing such A dealership to exist.
David LawrenceDavid Lawrence
13:04 22 Feb 24
Brandon PierceBrandon Pierce
22:00 18 Feb 24
Darin NoeDarin Noe
01:17 16 Feb 24
Jose SotoJose Soto
15:26 23 Sep 23
Hunter ElliottHunter Elliott
16:17 07 Sep 23
Rick Kelly-CrapseRick Kelly-Crapse
21:06 25 Aug 23
They had all my parts for my 3208 Cat.Friendly folks at parts counter.
js_loader