Engine Paralleling and Integration Control (EPIC) Configuration Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control) Modes of Operation Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel) Application LV and MV (208V-27kV) View Full Specs EMCP 4.4 Master Control Panel Configuration Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source. Modes of Operation Emergency standby, island, utility paralleling Application LV and MV (208V - 38 kV) View Full Specs Emergency Transfer Load manager Configuration Wall mounted paralleling control system that monitors and controls a single generator and a single utility. Modes of Operation Utility Import, Export, and base load operations, Peak shaving, and Emergency Standby. Closed Transition to/from Generator Power Application LV and MV (208V-32kV) View Full Specs Cat Switchgear Configuration IP4X Operating Temperature 35 °C / 40 °C @ 1 hr, option for 0ā¦50 °C (32ā¦122 °F) Standard Widths 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A. View Full Specs Cat EGP Switchgear Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications Modes of Operation Multi-unit Island and multi-unit standby mode with optional redundant controls and components. Application LV and MV (208V - 38 kV) View Full Specs Cat XLM Switchgear Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications Modes of Operation Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power Application LV and MV ( 208V - 38 kV View Full Specs Cat Customizable Switchgear and Controls Configuration Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc Modes of Operation All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow Application LV and MV ( 208V - 38 kV) 50 / 60 Hz View Full Specs